Your needs, this model
Does it fit your priorities?
Does 7,200 BTU/h SACC clear your minimum, or do you need an 8,000-SACC unit?
The exact U.S. sheet and EnergyGuide identify 7,200 BTU/h SACC (12,000 ASHRAE is a different rating). It passes a 7,100-SACC floor but not an 8,000-SACC floor.
Explore this need in the finder →Can you exhaust one hose through a hung or sliding window, or is dual hose essential?
The exact product page and manual show one exhaust hose and an included hung/sliding-window kit. No second exhaust path or numeric uncut panel endpoints are documented.
Explore this need in the finder →Is gravity drainage enough for continuous Dry mode, or do you need a lift pump?
The supplied continuous drain is gravity-only; the 2025 manual explicitly says there is no drain pump. A pump-essential setup is not supported.
Explore this need in the finder →Must the same appliance provide heat?
No heat mode is documented. The exact manual lists Auto, Cool, Dry and Fan only.
Explore this need in the finder →Do you need remote app access, and is an inverter compressor also mandatory?
Danby confirms wireless/app control for this exact model, but the documents do not identify an inverter compressor. App-only passes; an app-plus-inverter must-have does not.
Explore this need in the finder →Does the 72.8-pound product weight fit your handling ceiling?
The exact specification lists 72.8 lb. A 73-pound ceiling includes the listed weight; 72 pounds does not.
Explore this need in the finder →Will the 30.43-inch cabinet fit under your height limit?
The exact cabinet is 30.43 inches high before the manual-required airflow clearance; a 31-inch body limit fits the listed cabinet, while 30 inches does not.
Explore this need in the finder →Is a CEER floor of 8 essential?
The exact EnergyGuide gives CEER 7.0; an 8-or-higher requirement excludes it. Leaving this optional field empty imposes no such threshold.
Must the uncut window slider have a verified numerical span before it can be shortlisted?
The manual permits cutting the included kit for a shorter opening but does not state numeric uncut endpoints. No numeric-span requirement leaves it eligible; a filled numeric opening need fails until the exact range is confirmed.
The Danby DPA072B8WDB-6 is a white, single-hose portable air conditioner rated at 7,200 BTU/h SACC and 12,000 BTU/h ASHRAE. Those are different capacity methods: if your minimum is 7,100 SACC, this model meets the published number; an 8,000-SACC requirement is not met. Danby estimates cooling up to 350 square feet, but that is a starting point rather than a room-load guarantee. Sun exposure, insulation, ceiling height, people and heat-producing equipment change what a room needs.
A middle step in Danby's current range
Compared with the DPA065B6WDB-6, this model adds 700 BTU/h of SACC on paper and raises Danby's stated area estimate from 300 to 350 square feet. It also weighs 9.1 pounds more and stands 1.69 inches taller. If a true 7,100-SACC floor matters, that difference can be decisive; if the main issue is carrying the unit upstairs or fitting below a sill, the larger number alone may not justify it. The DPA080B1WDB-6 moves to 8,000 SACC, but its documented room-area information is conflicted and its app status is not confirmed. Compare the exact configurations rather than using the shared 12,000-BTU ASHRAE headline as a shortcut. See the DPA065 review, DPA080B1 review and three-model Danby capacity comparison.
Measure the whole setup, not just the cabinet
The manufacturer lists a 17.72-inch width, 14.09-inch depth, 30.43-inch height and 72.8-pound product weight. Four casters and side handles make room-to-room movement possible on suitable hard flooring, but this is still a substantial lift at stairs or a window sill. The 2025 manual calls for a level, sturdy floor, at least 12 inches of clearance at the front and sides, 20 inches behind the unit, and 20 inches between the horizontal louver and an obstacle. Add those clearances to the cabinet dimensions before deciding that a tight alcove will work.
The included kit is for hung or sliding windows. Danby's manual says the slider can be assembled from sections and trimmed for a shorter opening, but it does not give a numeric uncut minimum or maximum span in the reviewed instructions. If your lease, window construction or security plan makes trimming unacceptable—or the opening has to match a documented range—measure the supplied kit or get the exact range before buying. A casement window or a route with no safe exhaust opening is not solved by this portable design.
What operation and controls actually look like
The exact page and model-named manual document Auto, Cool, Dry and Fan modes. Cool and Auto need the exhaust hose connected to the window kit; Fan and Dry do not. Cool temperature is adjustable from 62 to 86°F. The appliance has two listed fan speeds, louver swing, Sleep, a timer, auto-restart and an included remote with Follow Me sensing. The remote's temperature sensor can make the unit respond to the temperature where the remote is placed, so keep it in the occupied area and within the manual's stated signal range rather than on a sunny sill.
Unlike the DPA065, DPA072 documentation does identify wireless connection and app control; the exact manual describes holding the panel's swing/wireless button to begin pairing. This is a real convenience if remote access matters, but it is not evidence of an inverter compressor. The reviewed product page, specification and manual do not establish an inverter drive or a heat mode. If either is an essential requirement, do not infer it from the wireless feature or the product-family name. Danby's claimed low operating figure is 45.5 dB; the detailed specification lists 45.5 dB low and 47.5 dB high. Those are manufacturer figures, not independent acoustic measurements or a guarantee of bedroom quiet.
Drainage is a gravity route, not a pump
For Dry mode, the manual says the exhaust hose is unnecessary and the supplied continuous-drain hose can be attached to the upper outlet. Danby states that there is no drain pump: the hose must travel continuously downward to a lower receptacle, without a kink or uphill section. If the internal pan fills, the appliance signals P1 and cooling or dehumidifying stops; the manual's other route is to switch off, unplug, move it where water can be collected and empty the lower drain. This is workable beside a floor drain or low sink, but not where condensate must be lifted to a standpipe or over a sill. The model does not turn a gravity drain into a pump just because the page calls it direct drain.
Energy label and ownership limits
The exact EnergyGuide gives a CEER of 7.0 and a $100 estimated yearly energy cost. The label explains its estimate assumes a national-average electricity rate of 13 cents per kWh and seasonal use of eight hours a day for three months. Treat that as a standardized comparison, not a forecast of your own bill. The product specification lists 115 V, 11.9 A, 1,350 W and a 59.1-inch cord; the manual requires a properly grounded wall receptacle and says not to use an extension cord or share the outlet. The manual also calls for cleaning the filters when its 250-hour reminder appears. That recurring task, the clearances and the exhaust route belong in the decision along with capacity.
Choose the DPA072B8WDB-6 when a verified 7,200-SACC rating, app/remote control, a single-hose hung or sliding window plan and gravity-only Dry drainage fit your home. Step down to a lighter or shorter unit if its weight and height are the sticking points; step up only when your room calculation calls for more capacity and the alternative's other constraints also work. Skip it if you need dual exhaust, heat, a built-in lift pump, a numeric uncut panel range, or a documented inverter. The exact manufacturer evidence is useful for those boundaries, but it is not a substitute for checking the window, outlet, drain slope and full airflow clearance in your room.
Key details at a glance
| DOE seasonal-adjusted cooling capacity | 7200 BTU/h |
|---|---|
| Manufacturer's stated room area | 350 sq ft (stated, not a guarantee) |
| Documented modes | auto / cool / dry / fan |
| Dual-hose exhaust arrangement | No |
| App or connected control | Yes |
| Manufacturer's lowest sound claim | 45.5 dBA (claim, not our measurement) |
| Combined energy efficiency ratio on EnergyGuide | 7 CEER |
| Cabinet width | 17.72 in |
| Cabinet height | 30.43 in |
| Cabinet depth | 14.09 in |
| Listed product weight | 72.8 lb |
| Listed limited warranty | 2 years |
| Built-in condensate pump | No |
| ASHRAE cooling rating (separate test method) | 12000 BTU/h |
| Supplemental heat documented | No |
Use the exact model’s instructions for operating limits, supplied equipment and version differences.
Sources for this assessment
- Danby U.S. current portable-AC category archive (13 results)
- Exact DPA072B8WDB-6 U.S. product page
- Exact page-linked DPA072 two-page product specification
- DPA072B8WDB-6 EnergyGuide
- DPA072/DPA086 model-named owner manual, 2025-03-20
- Danby U.S. recall listing bounded check
- Exact-page-linked DPA072 right-view image
Keep the model number in the decision.
Check the listed suffix, included vent kit, room conditions and service instructions before ordering.